Rocket R60V maintenance: what the manual says

Rocket’s manual lists 10 maintenance jobs for the R60V and forbids 1. Each is below with how often and the sentence it comes from.

What the manual says not to do

What to do, and how often

Job How often The manual’s sentence
Backflush (detergent) Every week

“Every week, after backflushing, add a small amount of espresso cleaning detergent to the blind basket.”

Backflush (water) Every day

“You should backflush the group head every day.”

Portafilter & basket soak If coffee oils have built up

“If the coffee oils have built up soak the metal end of the portafilter and basket in the same detergent solution as the shower foil and brass spreader above.”

Drip tray empty & clean No frequency given

“Remove the drip tray and wash with hot soapy water.”

Group gasket replacement When the head seal becomes brittle, or water escapes around the handle

“When the head seal becomes brittle or the shower foil gets punctured, they will need to be replaced.”

Shower screen clean When extraction is too slow

“Check the shower foil is not blocked - it may need to be back flushed or removed and cleaned.”

Shower screen replacement When the shower foil gets punctured

“When the head seal becomes brittle or the shower foil gets punctured, they will need to be replaced.”

Steam wand purge & wipe After every use

“Clean the steam nozzle after every use by wiping with a damp cloth.”

Steam wand deep clean If the steam jets get blocked

“If the steam jets get blocked with dry milk use a paper clip to unclog them.”

Water tank clean Periodically

“Remove and clean the water reservoir periodically with warm soapy water.”

The settings

Brew boiler temperature

Range: 95 to 115 °C.

“The coffee water boiler’s temperature is factory set to 105° C which reflects an extraction of around 92°C.”

Factory setting: 105 °C

“The coffee water boiler’s temperature is factory set to 105° C which reflects an extraction of around 92°C.”

Service boiler temperature

Range: 110 to 126 °C.

“The temperature of the service boiler is factory set to 123°C.”

Factory setting: 123 °C

“The temperature of the service boiler is factory set to 123°C.”

Step-by-step guides

What the manual does not say

4 jobs with nothing stated
  • Boiler water change
  • Group head wipe / flush
  • Professional service
  • Water filter / softener replacement
Notes from the research
  • No Rocket-hosted manual exists for this model; every value comes from Rocket's own range manual rehosted by a retailer, so the basis is community by host.
  • Drip tray has a procedure but no frequency; group-head wipe, water-filter replacement, boiler water change and professional service are not stated.
  • R60V is discontinued; no newer manual exists.

Sources

Researched on .

Published: the sentence is on the maker’s own page or in the maker’s own document.