ShotPulled › Gear › Backflush (water)
Backflush the group with water only: ECM Classika PID
Before you start
- Tools
- blind filter (supplied), portafilter
- Supplies
- None listed
Warnings
- Hot water can spray from the group during cleaning. Source: ECM Classika PID user manual, multilingual (2412)
Steps
- Heat the machine up to its working temperature.
From the manual: “Heat up the machine until the optimum operating temperature is reached.”
- Fit the blind filter in the portafilter and add no cleaner.
From the manual: “It´s better if you clean the brew group from time to time without cleaner.”
- Lock the portafilter into the group.
From the manual: “Place the portafilter in the group head.”
- Raise the brew lever for about 20 seconds so the blind filter fills.
From the manual: “Operate the group lever for approx. 20 seconds.”
- Hold the lever in its middle position, about 45°.
From the manual: “moving the group lever into the middle position.”
- After about 20 seconds, lower the lever fully so the water drains through the group.
From the manual: “Move the lever into the lower position after approx. 20 seconds.”
- Repeat several times, until only clear water comes out. Repeat until the discharge runs clear
From the manual: “until only clear water is discharged by the infusion cylinder”
- Swap the blind filter for your coffee basket.
From the manual: “Exchange the blind filter for the coffee filter”
Sources
Researched on .
Published: the sentence is on the maker’s own page or in the maker’s own document.