ECM’s manual lists 13 maintenance jobs for the Classika PID. Each is below with how often and the sentence it comes from.

What to do, and how often

Job How often The manual’s sentence
Backflush (detergent) Every 90 shots

“A cleaning should be done after about 90 - 140 times.”

Backflush (water) From time to time, without cleaner

“It´s better if you clean the brew group from time to time without cleaner.”

Portafilter & basket soak Daily

“Portafilter, filters, water tank, drip tray, drip plate of the drip tray, measuring-spoon and tamper require daily cleaning.”

Boiler water change Every week

“Depending on usage, please refresh the boiler water every 1 – 2 weeks by operating the pump switch and extracting about 0.8L of hot water from the steam/hot water wand.”

Descale When needed

“If these measures are insufficient, a prophylactic descaling of the machine may be necessary.”

Drip tray empty & clean Daily; empty before it is full

“Portafilter, filters, water tank, drip tray, drip plate of the drip tray, measuring-spoon and tamper require daily cleaning.”

Group gasket replacement When the portafilter cannot be locked as usual, or water runs over the portafilter

“If the portafilter cannot be locked as usual.”

Group head wipe / flush Daily

“Clean the shower screen and the group gasket in the lower part of the group and remove visible dirt without disassembling the parts.”

Shower screen replacement When the portafilter cannot be locked as usual, or water runs over the portafilter

“If the portafilter cannot be locked as usual.”

Steam wand purge & wipe After every use

“Clean the steam nozzle and the steam dispenser after every use with a damp cloth in order to remove possible liquid residues.”

Steam wand deep clean When the steam nozzle is blocked

“Clean the holes of the steam nozzle carefully with a needle or a paper clip.”

Water tank clean Daily

“Portafilter, filters, water tank, drip tray, drip plate of the drip tray, measuring-spoon and tamper require daily cleaning.”

Left to a technician

Job How often The manual’s sentence
Professional service Depending on use and operating time, by an ECM dealer or ECM

“An ECM machine should be serviced depending on its use and operating time.”

The settings

Coffee temperature (t1)

“The PID-Temperature control allows you to adjust the current temperature of the coffee and the steam.”

Factory setting: 93 °C

“The coffee temperature control is pre-programmed to 93°C and the steam temperature to 130°C.”

Steam temperature (St)

“The PID-Temperature control allows you to adjust the current temperature of the coffee and the steam.”

Factory setting: 130 °C

“The coffee temperature control is pre-programmed to 93°C and the steam temperature to 130°C.”

Step-by-step guides

What the manual does not say

2 jobs with nothing stated
  • Shower screen clean
  • Water filter / softener replacement
Notes from the research
  • Descale: the manual makes it conditional (contact dealer first; calcified machine dealer-only); the brand-wide FAQ's 3/6-month interval is recorded as the non-preferred alternative.
  • No water-filter cartridge or interval; gasket/shower-screen replacement only on symptoms; service interval not given in years.