Replace the dispersion screen: Slayer Single Group

Before you start

Tools
flat-head screwdriver, cleaning brush or towel
Supplies
replacement dispersion (shower) screen (Slayer original)

Warnings

Steps

  1. Scrub the portafilter gasket with a cleaning brush or towel to loosen oil and grounds.

    From the manual: “Use a cleaning brush or towel to scrub the portafilter gasket and loosen oil and coffee grounds.”

  2. Take out the dispersion screw and screen with a flat-head screwdriver and rinse them in clean water.

    From the manual: “Remove the dispersion screw and screen with a flat-head screwdriver and rinse with clean water.”

  3. Wipe the face and sides of the dispersion block, and the portafilter body, with a clean damp towel.

    From the manual: “wipe oil and grounds from the face and sides of the dispersion block, as well as the portafilter body.”

  4. Throw away the old dispersion screen.

    From the manual: “Discard old dispersion screen.”

  5. Fit the new screen and secure it with the same screw, tightening by hand until snug.

    From the manual: “Install new screen and secure with the screw from step 1, taking care not to over-tighten.”

  6. Give the screw a further quarter turn (90 degrees) with the screwdriver, and no more.

    From the manual: “then rotate an additional 90 degrees (1/4 turn) with the screwdriver.”