Before you start
- Tools
- blind filter (supplied), plastic group brush (supplied), group screen extractor (supplied)
- Supplies
- coffee dissolving powder (espresso machine cleaner) (1 teaspoon per backflush; a jar ships with the machine)
Warnings
- Always remove the filter holder between rinse flushes, or cleaning powder can lodge in the 3-way group valve. Source: Speedster 2020 installation and user manual
- Parts of the machine get close to 135 °C; keep hands off the group and boiler surfaces. Source: Speedster 2020 installation and user manual
Steps
- Take out the filter holder, lower the lever to run the pump, and flush the group for about 5 seconds.
From the manual: “Remove the filter holder, activate the pump (lever in lower position) and flush the group for approximately 5 seconds.”
- Scrub the group screen and the rubber group seal with the plastic group brush.
From the manual: “Clean the group screen and rubber group seal with the plastic group brush.”
- Lever the filter basket out of the holder with the extractor and put the blind filter in.
From the manual: “Pry the filter basket from the filter holder (see Figure 16) and replace it with the blind filter.”
- Add 1 teaspoon of coffee dissolving powder to the blind filter and lock the holder into the group.
From the manual: “Scoop 1 teaspoon of coffee dissolving powder in the blind filter and place the filter holder in the group.”
- Hold the lever down about 10 seconds until the pressure reaches a full 9 bar, then raise it to stop.
From the manual: “Activate the pump until full 9 bar pressure is reached (lever in lower position for approximately 10 seconds)”
- Wait about 5 seconds so the pre-infusion cylinder empties, then run the pump again for about 10 seconds.
From the manual: “Wait for approximately 5 seconds (the pre-infusion cylinder should have time to empty) then activate the pump again”
- Repeat that 5-second pause and 10-second pump run nine more times. Repeat 9
From the manual: “Repeat the last step 9 times (wait 5 seconds, activate pump 10 seconds).”
- Unlock the filter holder and rinse the blind filter under the tap.
From the manual: “Remove the filter holder from the group, clean the blind filter by flushing it under the tap”
- Run the pump about 5 seconds with no holder in to wash powder off the group screen.
From the manual: “activate the pump for approximately 5 seconds to remove possible powder from the group screen”
- Rinse with 4 more cycles of 5 seconds off and 10 seconds pumping, taking the holder out and emptying it between each. Repeat 4
From the manual: “Repeat step 6 (5 seconds group “OFF”, 10 seconds “pump active”) 4 times”
- Pry out the blind filter and refit the normal filter basket.
From the manual: “Pry the blind filter from the filter holder and replace the filter basket.”