ShotPulled › Gear › Group gasket replacement
Replace the group gasket and shower screen: Gaggia Classic Pro
Before you start
- Tools
- short Phillips screwdriver, 5 mm Allen key, large flat-blade screwdriver, needle-nose pliers, two pointed screws (for a stuck gasket), stiff brush
- Supplies
- Gaggia group gasket (part GA-NG01/001 (per Whole Latte Love)); Gaggia shower screen (when replacing the screen), optional
Warnings
- Take care not to damage the ridge the shower screen sits in when prying the plate. Source: Whole Latte Love: How to replace the group gasket on Gaggia semi-automatics
- Turn the gripping screws in only far enough to hold; do not go through the gasket. Source: Whole Latte Love: How to replace the group gasket on Gaggia semi-automatics
- Whole Latte Love suggests descaler on the brush for tough deposits; Gaggia allows only its own descaler in this machine, so use nothing else. Source: Gaggia Classic Pro (RI9380) user manual, USA
Steps
- Switch off, unplug and let the machine cool completely.
From the manual: “Make sure that the machine is powered down, unplugged, and completely cool”
- Take off the reservoir, drip tray, drip pan and reservoir cover, and lay the machine on its back.
From the manual: “lay the entire machine on its back”
- Undo the shower screen screw with a short Phillips screwdriver and take the screen off.
From the manual: “Use a short Philips head screwdriver to remove the shower screen.”
- Remove the two Allen screws holding the shower holding plate with a 5 mm key.
From the manual: “Remove the two Allen screws with 5mm Allen wrench.”
- Let the plate drop out, or ease it out gently with a large flat-blade screwdriver.
From the manual: “use a large flat blade screwdriver to gently pry out the Shower Holding Plate”
- If the plate is seized, put the tips of open needle-nose pliers in the empty screw holes and twist hard. Optional
From the manual: “stick the points into the holes where the Allen bolts were”
- Pull the old gasket out.
From the manual: “You should now be able to pull out your old group gasket.”
- If it is hard or stuck, turn two pointed screws partway into it on opposite sides and pull it out with pliers, one side then the other. Optional
From the manual: “Screw them into the old gasket. Make sure that they are across from each other.”
- A very old gasket may have to come out piece by piece with needle-nose pliers. Optional
From the manual: “A gasket can be so old that it will need to be removed in bits and pieces”
- Scrub the screen, holding plate and group with a stiff brush.
From the manual: “This is a good opportunity to clean the shower screen and brew group.”
- Clean the gasket groove and dry it.
From the manual: “Clean and dry the slot in the machine that the gasket fits into.”
- Slide the new gasket into the groove.
From the manual: “Slide a new gasket into place.”
- Screw the holding plate back in, then the shower screen (a new one if you are replacing it).
From the manual: “screwing in the Shower Holding Plate and shower Screen”
- Lock the portafilter in firmly a couple of times to seat everything.
From the manual: “Lock the portafilter on a couple of times hard”
- Stand the machine up and refit the drip pan, drip tray and reservoir, then fill and plug in.
From the manual: “Tip the unit back up and install the drip pan, drip tray and water reservoir.”
Sources
- Whole Latte Love: How to replace the group gasket on Gaggia semi-automatics Retailer
- Whole Latte Love support: Gaggia Classic Pro grouphead cleaning and service (parts list) Retailer
- Gaggia Classic Pro (RI9380) user manual, USA Manual
Researched on .