Backflush the group with cleaner: ECM Puristika

Before you start

Tools
blind filter (supplied), portafilter, coffee filter basket to refit afterwards
Supplies
ECM group cleaning powder (about 3-5 g per clean)

Warnings

The machine tells you when

This machine keeps count itself and tells you when this job is due, so follow the machine rather than a calendar.

What you see
'CLn' on the PID display
Shown as
A message on the display
What it counts
Shots
Depends on
CLn reminder in the PID menu: 0-200 brews in steps of 10; 0 (the delivery setting) means no reminder. Only brews over 15 s count.
How it clears
counts down from 10 to 1 with each brew-lever operation after it appears, then the temperature returns and the counter restarts
Can be switched off
Yes

Source: ECM Puristika user manual, multilingual (2407)

Steps

  1. Heat the machine up to its working temperature.

    From the manual: “Heat up the machine until the optimum operating temperature has been reached.”

  2. Fit the blind filter in the portafilter.

    From the manual: “Place the blind filter into the portafilter.”

  3. Put about 3-5 g of group cleaning powder in the blind filter.

    From the manual: “Put approx. 3 – 5g of the group cleaning powder into the blind filter.”

  4. Lock the portafilter into the group.

    From the manual: “Clamp the portafilter into the brew group.”

  5. Lift the brew lever; the blind filter fills with water.

    From the manual: “Operate the group lever. The blind filter will be filled with water.”

  6. Move the lever to its middle position, about 45°, and let the cleaner work; do not lower it fully.

    From the manual: “Let the detergent react, moving the group lever into the middle position, approx. 45°.”

  7. After about 20 seconds, lower the lever fully so the grease drains through the group.

    From the manual: “Move the lever into the lower position after approx. 20 seconds.”

  8. Repeat the lift, hold and lower cycle up to 10 times, until the discharge runs clear. Repeat up to 10 times, until the discharge runs clear

    From the manual: “Repeat steps 5-7 up to 10 times, until only clear water is discharged by the infusion cylinder.”

  9. Rinse the portafilter and blind filter under fresh water and lock the portafilter back in.

    From the manual: “Rinse the portafilter and the blind filter with fresh water. Then replace it.”

  10. Run the lever for about one minute, then lower it.

    From the manual: “Operate the group lever for approx. one minute.”

  11. Take the portafilter out, rinse it and run that flush once more.

    From the manual: “Remove the portafilter and repeat point 10.”

  12. Put the 1- or 2-cup filter back in the portafilter.

    From the manual: “Place the filter for 1 or 2 cups into the portafilter.”

  13. If a CLn reminder is programmed, it clears after 10 lever operations and the counter restarts. Only when: if the CLn reminder is programmed

    From the manual: “will disappear on the display after having operated the brew group lever 10 times”