ShotPulled › Gear › Group gasket replacement
Replace the group head gasket: Decent Espresso DE1, Decent Espresso DE1PRO and Decent Espresso DE1XL
Before you start
- Tools
- Decent gasket removal tool (thin dental-style pick), blind basket
- Supplies
- Decent silicone group head gasket (ID 57 mm, 8.5 mm thick (fits the DE1)); NBR rubber group head gasket (alternative) (ID 58 mm, 7.5 mm thick), optional
Warnings
- Do not over-tighten the portafilter, especially on a hot machine: it ages the gasket early. Source: Decent blog: Gasket removal tool & deep dive video (with summary)
Steps
- Slip the removal tool in along the outer edge of the old gasket.
From the manual: “Slide the gasket removal tool through the outside edge of the gasket.”
- Push the tool upwards past the gasket.
From the manual: “2. Push it up,”
- Turn the tool so its tip hooks over the top of the gasket.
From the manual: “Then rotate the tool so that the edge of the tool catches the top of the gasket.”
- Pull downwards to draw the gasket out of the group.
From the manual: “the top of the gasket. 4. Then pull down.”
- Fit the new gasket with the side marked UP facing up into the group.
From the manual: “The top side is marked UP so it's easier to know which direction to put it in for a correct seal.”
- Lock in a portafilter with the blind basket to seat the new gasket evenly.
From the manual: “A blind basket is used to reseat the gasket to ensure a proper seal.”
Sources
- Decent docs: How to repair guides (31. How to replace your gasket) Maker’s support page
- Decent Espresso: Gasket and removal tools Maker’s page
- Decent blog: Gasket removal tool & deep dive video (with summary) Maker’s page
Researched on .