Change a bestmax PREMIUM cartridge and flush it in: BWT bestmax PREMIUM S, BWT bestmax PREMIUM V and BWT bestmax PREMIUM M
Before you start
- Tools
- 10 litre container, total hardness drop test (or the water supplier's figure)
- Supplies
- BWT bestmax PREMIUM filter cartridge (S (FS22P00A00), V (FS23P00A00) or M (FS24P00A00), same size as before)
Warnings
- Replace the cartridge within 12 months of commissioning however much capacity is left. Source: BWT bestmax PREMIUM installation and operating instructions (multilingual; EN section), BWT Denmark download
- A shutdown of 4 weeks or more means a new cartridge. Source: BWT bestmax PREMIUM installation and operating instructions (multilingual; EN section), BWT Denmark download
- After a break of more than two days, flush 4-5 litres through before use. Source: BWT bestmax PREMIUM installation and operating instructions (multilingual; EN section), BWT Denmark download
- Do not send the flushing water straight into the boiler. Source: BWT bestmax PREMIUM installation and operating instructions (multilingual; EN section), BWT Denmark download
- Use only a genuine BWT filter head. Source: BWT bestmax PREMIUM installation and operating instructions (multilingual; EN section), BWT Denmark download
- Descale the machine before a filter goes on it for the first time. Source: BWT bestmax PREMIUM installation and operating instructions (multilingual; EN section), BWT Denmark download
- BWT reserves installation and maintenance for trained people. Source: BWT bestmax PREMIUM installation and operating instructions (multilingual; EN section), BWT Denmark download
Steps
- Shut the stop valve upstream of the filter.
From the manual: “Close the existing check valve before replacing the filter cartridge!”
- Unscrew the old cartridge clockwise; rotating the head 90 degrees in its bracket makes this easier.
From the manual: “Unscrew the filter cartridge out of the filter head in a clockwise motion”
- Check whether your water's total hardness has changed, and adjust the bypass and change interval if it has.
From the manual: “Check whether the total hardness of the natural water has changed and adjust the replacement intervals and bypass setting”
- Get the total hardness from the water supplier or with the drop test.
From the manual: “The total hardness can be requested from the water supplier or established by means of a quick test”
- Pick the bypass (0-3) from the tables; for machines that make steam BWT lists 3 up to 10 °dH, 2 at 12-14 and 1 from 17.
From the manual: “Hot beverage preparation with steam generation”
- Turn the head's cap until its mark shows that setting and it clicks home (the default is 2).
From the manual: “Turn the cap left or right until the mark displays the required value and the cap snaps into place.”
- Lock the setting with the warranty label from the box. Only when: after changing the bypass
From the manual: “Once the bypass has been set, it can be fixed using the enclosed warranty label.”
- Take the new cartridge out of its film and pull off the hygiene cap.
From the manual: “Take the filter cartridge from the packaging film and remove the hygiene cap.”
- Mark the fitting date and a change-by date no more than 12 months later on the cartridge's rating plate.
From the manual: “mark the installation date and the replacement date (no later than 12 months) on the filter’s rating plate”
- Screw the new cartridge into the head anticlockwise.
From the manual: “Turn the filter anticlockwise in the filter head”
- Open the stop valve.
From the manual: “Open the check valve. 5. During commissioning”
- Flush and bleed it with at least the minimum volume: 1 l for S, 3 l for V, 5 l for M.
From the manual: “During commissioning, the filter must be flushed and bled”
- Flush through the machine's filter start-up function if it has one. Optional
From the manual: “the filter system can be bled/flushed from the appliance”
- Or flush through a flushing valve fitted at the filter outlet. Optional
From the manual: “the filter can easily be bled and flushed via this flushing valve”
- Otherwise close the stop valve and pull the outlet hose off the machine. Only when: if neither the machine nor a flushing valve can flush it
From the manual: “Disconnect the water outlet hose from the appliance, e.g. coffee machine.”
- Hold the hose end in a 10 litre container and open the valve. Only when: if neither the machine nor a flushing valve can flush it
From the manual: “Attach the end of the hose to the 10 litre container below.”
- Let it run until the water comes out clear and without bubbles. Only when: if neither the machine nor a flushing valve can flush it Repeat until clear and bubble-free
From the manual: “Flush/bleed the filter system until bubble-free and clear filtered water emerges”
- Close the valve, reconnect the hose to the machine and open the valve again. Only when: if neither the machine nor a flushing valve can flush it
From the manual: “Refit the water outlet hose onto the appliance.”
- Check the filter and every connection for leaks.
From the manual: “Check the filter system and all connections for leaks.”
- Throw the old cartridge away according to local rules.
From the manual: “Dispose of the removed filter cartridge; observe the local disposal regulations.”
Sources
- BWT bestmax PREMIUM installation and operating instructions (multilingual; EN section), BWT Denmark download Manual
- BWT bestmax PREMIUM datasheet (EN), bwt-wam 01/2025 Maker’s support page
Researched on .
Published: the sentence is on the maker’s own page or in the maker’s own document.
Applies to
- BWT bestmax PREMIUM S
- BWT bestmax PREMIUM V
- BWT bestmax PREMIUM M