Breville / Sage Bambino Plus (BES500) maintenance: what the manual says

Sage’s manual lists 8 maintenance jobs for the Bambino Plus. Each is below with how often and the sentence it comes from.

What to do, and how often

Job How often The manual’s sentence
Backflush (detergent) Every 200 shots

“The machine will detect when 200 extractions have been carried out since the last cleaning cycle; this will be shown by the 1 CUP and 2 CUP buttons alternately flashing.”

Descale When 1 CUP/STEAM and 2 CUP flash alternately for 15 s

“The machine will indicate that it requires descaling when the 1 CUP and STEAM button and the 2 CUP button flash alternately for 15 seconds.”

Drip tray empty & clean After each use or when the indicator rises through the grid

“The drip tray should be removed, emptied and cleaned after each use or when the drip tray indicator rises through the drip tray grid.”

Group head wipe / flush Periodically

“Periodically run hot water through the machine with the filter basket and portafilter in place, without any ground coffee, to rinse out any residual coffee.”

Professional service Any maintenance other than cleaning

“Any maintenance other than cleaning should be performed by an authorised Sage® service centre.”

Steam wand purge & wipe After texturing milk

“The steam wand should always be cleaned after texturing milk.”

Steam wand deep clean When the tip stays blocked after a manual purge

“If the steam wand remains blocked, unscrew the steam wand tip using the steam tip cleaning tool.”

Water filter / softener replacement Every 3 months or every 40 litres of water, whichever comes first

“Replacing the water filter after 3 months or 40L will reduce the need to descale the machine.”

Step-by-step guides

What the manual does not say

7 jobs with nothing stated
  • Backflush (water)
  • Portafilter & basket soak
  • Group gasket replacement
  • Automatic milk system clean
  • Shower screen clean
  • Shower screen replacement
  • Water tank clean
  • Settings the owner can change
Notes from the research
  • Descale has no day/shot interval or hardness table — only the machine alert.
  • No basket/portafilter detergent soak, group gasket replacement, shower screen replacement, water tank cleaning or service interval stated.
  • The water filter cartridge is not named; the Breville US manual has no filter.