La Pavoni Casabar PID Steel maintenance: what the manual says
La Pavoni’s manual lists 7 maintenance jobs for the Casabar PID Steel. Each is below with how often and the sentence it comes from.
What to do, and how often
| Job | How often | The manual’s sentence |
|---|---|---|
| Portafilter & basket soak | Regularly (no interval given) |
|
| Professional service | After a malfunction or damage |
|
| Shower screen clean | When the shower screen is dirty and no coffee is dispensed |
|
| Shower screen replacement | When a dirty screen stops coffee flowing |
|
| Steam wand purge & wipe | After use |
|
| Steam wand deep clean | When the steam nozzle hole is clogged |
|
Left to a technician
| Job | How often | The manual’s sentence |
|---|---|---|
| Group gasket replacement | When coffee leaks between the group and the filter holder |
|
The settings
PID temperature controller (11)
Range: 80 to 99 °C.
“when the temperature of the boiler appears on the display, use the and to set the buttons temperature, from a minimum of 80°C to a maximum of 99°C.”
Factory setting: 92 °C
“The PID temperature controller is factory set to 92°C.”
What the manual does not say
8 jobs with nothing stated
- Backflush (detergent)
- Backflush (water)
- Boiler water change
- Descale
- Drip tray empty & clean
- Group head wipe / flush
- Water filter / softener replacement
- Water tank clean
Notes from the research
- A blind filter is supplied but no backflush procedure or interval is given in the manual text.
- No descale, water tank, drip tray or boiler water guidance.
- No interval for the filter soak ('regularly' only).
Sources
Researched on .
Published: the sentence is on the maker’s own page or in the maker’s own document.